Fire Proof Subfloor: Redefine Structural Safety for Flooring When selecting subfloor materials, our MGO Fire Proof Subfloor stands out with its inherent fireproof superiority. As an A1 non - combustible material, it neither burns nor emits smoke during fires, fundamentally blocking fire spread—an edge that wood-based panels (like plywood and OSB) can’t match. Traditional wood composites are highly flammable and release toxic fumes when ignited. Traditional wood composites are highly flammable and release toxic fumes when ignited.

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction

product-700-700

 

Product Introduction

 

MGO Fire Proof Subfloor:
Our Fire Proof Subfloor is engineered with inorganic materials, delivering unmatched fire resistance through its core composition: magnesium oxide, magnesium chloride or magnesium sulfate, water, and inert fillers. Unlike traditional materials, our Fire Proof Subfloor is naturally non-combustible, eliminating any risk of burning or smoke-even under extreme heat. This inherent safety stems from its chemical structure, not artificial treatments. While other materials depend on fire-retardant coatings, our Fire Proof Subfloor achieves true fire safety through its solid inorganic matrix.

 

Unlike treated materials, our Fire Proof Subfloor naturally blocks flames (no chemical additives needed), protects building integrity for over 120 minutes per ASTM E119 and carries the gold-standard A1 fire rating. For both commercial and residential projects, our Fire Proof Subfloor combines unmatched fire protection with structural strength. It is about 30% lighter than cement fiberboards of equal strength. Where safety, light weight and performance are critical, this is the proven choice.

 

 

 

Parameters:

Main Materials

MgO, MgCl2/MgSO4, Glass fiber Mesh

Fire Performance

Non-combustible, No flame spread, No smoke spread,No poisonous gas

Density

1.15-1.35kg/m3,

Flexural Strength

16-40Mpa

Impact Strength

≥3.5 kJ/m2

Moisture Content

≤8%

Shrinkage

≤0.3%

Swelling

≤0.3%

Screw Holding Capacity

50-100/(N/mm)

Leachable Chloride

0.1%(MOS),3%(MOC)

Edge

Square/T&G/Tapered/Beveled

Thickness

15-20mm

Standard Sizes

4*8ft/1.22*2.44m(Other sizes can be customized)

Production Capacity

5000 square meters / day

Remark

The above parameters are acceptable to ODM

product-800-800

 

advantage

Workshop Information:

 

Specializing in the durability of building materials, we have established ourselves as a leading provider in the local fireproof flooring sector by offering robust, fire-resistant boards.

 

Our rigorous full-process quality control system ensures consistency at every stage:

   1. Incoming Quality Control (IQC) for raw materials to verify baseline standards

   2. In-Process Quality Control (IPQC) with continuous monitoring of critical production phases
  3. Outgoing Quality Control (OQC) covering final cutting, packaging, and comprehensive checks before dispatch.


All our finished products adhere to national and industry benchmarks, undergoing thorough testing against standards such as GB/T 33544 or T/CMMA8-2020. We also accommodate custom testing requirements specified by clients, ensuring that only inspected and certified products are released for delivery. This commitment to quality has solidified our reputation for reliability in fireproof building solutions.

product-700-700

 

Packing and Shipping:

To ensure panels are protected during transit, we implement meticulous packaging protocols.

 

product-800-718

 

 

Product Transportation Notes

Before transporting Fire Proof Subfloor, it is essential to ensure that its packaging is intact and securely fastened. Due to the weight and volume of these panels, specialized transportation packaging materials like shockproof foam and wooden strips should be utilized to offer comprehensive protection. Additionally, straps and ropes should be employed to secure the panels onto the transport vehicle, preventing damage caused by shaking during transit.

 

FAQ:

 

Q1: How many hours of fire rating can MgO products achieve?
A: When installed as components of third-party tested and rated assemblies, MgO boards are well-suited for wall and floor constructions. Depending on the specific assembly configuration, they can achieve fire ratings ranging from 1 to 4 hours.


Q2: How do MgO products contribute to fire resistance?
A: Fire resistance is critical for safeguarding occupants, visitors, firefighters, and first responders. MgO products feature inherent non-combustibility and straightforward installation, which streamlines the construction of fire-rated assemblies-thereby ensuring both reliability and efficiency in fire protection.

 

Hot Tags: fire proof subfloor, China fire proof subfloor manufacturers, suppliers, factory, Fire Resistant Flooring, Fire Resistant Flooring Board, Exterior Deck, Mgo Flooring, Termite Resistant Subfloor, Fire Rated Subfloor